top of page

Customer:

Cork University Hospital     

 

Site Type:

Hospital Extension 12000M2. 

 

Coverage Requirement:

Full Multi-operator / Multi technology DAS inbuilding solution.

 

Building construction Phase:

Mid build / 2nd fix

 

Project Description:

Design, installation and commissioning and full handover of an in-building repeater solution to provide full coverage, all mobile technologies (G900 U900, & U2100).  Full compliance to Health & Safety and welfare at work act – 2005.

 

Client: Cork University Hospital

Project Duration: 6 months 

Project management: Fully project managed by Surecom 

 

Responsibilities: 

 

  • Role PSDS 

    • Responsibilities: Solution Design (TEMs walk test, iBuildnet design coverage predictions, Antenna location verification – CW testing, BOM, MNO Design approval.)

  • Role PSCS 

    • Responsibilities: (BOM logistics-onsite), Main Contractor liaison and communication– site in construction phase, H&S compliance supporting site main contractor rules and co-operation to allow for working alongside other companies on site, Sample installation of the cable and antenna to support and agree methodology. 

    • Installation of solution to the design specifications (Cable [Co-axial-leaky feeder], Fibre & power), antennae, Radio units). Inclusive of “as build” handover.

    • Commissioning – Cable testing (Sitemaster & fibre), commissioning & optimisation, handover - walk and coverage 

    • Project management – Daily & weekly on-site meeting, weekly & monthly checkpoint & highlight reporting-6.

  • Team 

    • Project Manager  

    • Design Engineer X 1

    • Installation team of 6 men 

    • Health and Safety Officer 

bottom of page